Lexington Elem. Schools <br />Master Plan Study <br />Bowman Elementary School <br />Executive Summary — Electrical <br />The existing electrical systems in general, although functioning, are at the end or have exceeded <br />their useful life. Even with regular maintenance systems do deteriorate over the years. The life <br />safety systems, due to code changes over the years, are not in complian, with current codes. <br />Existing Conditions <br />• The primary service runs overhead and feeds a 300 kva Utility Co. owned pad mounted <br />transformer. Secondary service runs underground in one (1) 4" conduit. The secondary <br />electrical service consists of a main switch rated at 400amp, 277/480 volt, 30, 4wire, a <br />C/T cabinet and meter with a distribution panel. The equipment is located in the <br />custodian's work room. Lighting and power panels are circuit breaker type and are rated <br />at 120/208 volt and 277/480 volt, 30, 3wire. The existing panels do not appear to have <br />spare circuit breakers for the addition of new lighting and power circuits. Dry type <br />transformers are used for receptacle power. Most equipment was manufactured by <br />General Electric. Various panels do not have required working clearance. The condition <br />of the equipment is poor and has exceeded its useful life_ <br />4044 <br />• Existing classroom lighting consists of (3) continuous rows of wraparound fixtures <br />parallel with the exterior wall. Lights are controlled with one switch. No occupancy <br />sensor exists. <br />Stage lighting comprises of floor lights in front and track fixtures at stage. <br />2 x 4 recessed fixtures are used in the Gymnasium with four (4) T51-10 lamps and are in <br />good condition. <br />Kitchen lighting is through vaportight 4' fluorescent fixtures. <br />Corridor lighting consists of wall mounted 1 x 4 surface wraparound fixtures. Corridors <br />are controlled with local switches. <br />Although lighting has been retrofitted with T8 lamps and electronic ballasts, fixtures are <br />generally old and in poor condition. <br />• Existing site lighting consists of cobra heads on utility poles. The site appears to be dark. <br />Building mounted metal halide floods also exist on photocell. Surface canopy lights of <br />compact fluorescent exist at front and rear entrances. <br />• The existing emergency lighting system is through a LP gas generator rated at 12.5KW, <br />277/480v, 30, 4W and is manufactured by Onan. One automatic transfer switch <br />manufactured by Onan is present. The system is not code compliant and the equipment is <br />in poor condition. Retrofitted LED exit signs exist. There is inadequate coverage of exit <br />signs. <br />